Q:What are the connection methods for the sensor?

A:Lead way - connected by cable leads Terminal mode - connected by terminal block Socket mode - connected through the socket.

Q:Position setting of the detector ?

A:The sensing distance of sensor varies slightly depending on changes in ambient temperature and voltage fluctuations. Therefore, in order to make the sensor work stably, the maximum approach position of the sample body needs to be smaller than the sensing distance. When using standard test, actual sensing distance should be set to be less than 80% of the operating distance. Further, when the shape of sample is smaller than the standard sample or the sample is not iron, the actual sensing distance must be shortened accordingly considering shortened sensing distance.    

 